Ariston
Showers
Aqualisa
- Colt - Dripping shower cartridge replacement Aqualisa Cartridge Grey 022801
- Midas 100 Faulty Thermostatic Cartridge 518101
- Aquavalve 609 thermostatic
- Aquavalve 409 manual shower valve is dripping
Armitage Shanks
Bristan
- Prism - No water. Faulty Flow Diverter Cartridge (APT 04895)
- CART18 Faulty Push-In Thermostatic Cartridge 06734B - No hot water
- Concealed thermostatic valve - thermostatic cartridge 00650410
- Chill Concealed 3 Control Shower Valve - Faulty Thermostatic Cartridge (Threaded) - 00622415
Crosswater
- flow cartridge (x2A071N) leaking
- CP0000250 Thermostatic Cartridge Failure
- Belgravia Exposed Valve not regulating water temperature correctly
- minimalistic shower bar - Crosswater Flow Valve replacement (CROSS-CG1210FA1)
- SOL - Thermostatic cartridge replacement
- SME-029 Thermostatic shower - Temperature and pressure problem
Crosswater
- flow cartridge (x2A071N) leaking
- CP0000250 Thermostatic Cartridge Failure
- Belgravia Exposed Valve not regulating water temperature correctly
- minimalistic shower bar - Crosswater Flow Valve replacement (CROSS-CG1210FA1)
- SOL - Thermostatic cartridge replacement
- SME-029 Thermostatic shower - Temperature and pressure problem
Grohe
- 47600000: Temperature and Flow Rate Problems
- faulty Kohler 78913 Thermostatic 3/4 inch Cartridge
- Sentosa - Water is constantly leaking from a bath filler
- Auto 2000 - temperature flactuation
HUB-001A-WAX Vado Thermostatic Cartridge
Hansgrohe
Hudson Reed
- Thermostatic Cartridge for SNINASF CEL-001A-WAX Ultra, Hudson Reed, Vado, Crosswater
- Ultra Hudson Reed SA30049 faulty Thermostatic Cartridge
- Traditional Dual Exposed Thermostatic Shower Valve ITY309 - Thermostatic cartridge replacement DC70T
- Kia/Jule A3010 - water is not getting hot
IB
- Rubinetterie - faulty thermostatic cartridge replacement CP0000250
- Crosswater - Non Return Valve IBNRV replacement
- Rubinetterie - Thermostat does not turn
- Hot water is lukewarm
Mira
- Discovery - Constantly leaking from a shower head (Flow Control 1.1609.042.2)
- Discovery shower turn on and off control knob is brocken
- 723 - thermostatic cartridge replacement (High pressure 902.70)
- Realm post 1993 - dripping from a shower head
- Crescent Cheltenham
Porcelanosa
- Eurohub V54001A - faulty Thermostatic cartridge SH-U960016AA
- Noken NK - CICE France OPTIMA 40 TH F Thermostatic Cartridge
- System Pool Tina shower valve temperature control is too stiff
S960134NU Thermostatic Cartridge
Sirrus Rothwell R995 Antique Shower
Swadling
Trevi
- E4705AA Trevi wall outlet assembly replacement
- THERM HP A2443 (314) Wall Mounted Thermostatic Bath/Shower Mixer - Flow cartridge replacement
- No water coming out when the shower is opened
- Therm MK2 - no hot water
Triton
- Thermostatic cartridge 83307770 Replacement Tips
- Combi HP - thermostatic shower water is too cold
- Dart 3 Thermostatic Cartridge Service Kit 8
- 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water
- Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120
- Unichrome Tees temperature control is too stiff
Triton
- Thermostatic cartridge 83307770 Replacement Tips
- Combi HP - thermostatic shower water is too cold
- Dart 3 Thermostatic Cartridge Service Kit 8
- 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water
- Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120
- Unichrome Tees temperature control is too stiff
Ultra
Vado
Vola
Boilers
Alfa Laval
Alpha
- CD35C - No hot water, heating start working when hot tap is opened
- CB28x - Red and Amber light are on - Faulty PCB (1.017118)
- CD50 - no lights - Faulty PCB (1.027267)
Ariston
- Microgenus 32HE MFFI E34 error code Faulty fan (65102567)
- Microcombi 23 MFFI - Boiler flue replacement
- Microgenus 23 MFFI - Faulty PCB 65101732
- Microcombi 23 MFFI - Ariston Low Water Pressure Switch 995903
- Microcombi 23 MFFI - PCB replacement 65100248
- Microgenus 23 MFFI - Pump fault
- Microgenus 23 MFFI - PCB problem. Knocking and rattling noise coming from the gas valve.
- Microgenus HE Combi Boiler - Fault A03
- Eurocombi A23 MFFI - No hot water but heating is working
- MicroGenus II 28 MFFI - mechanical timer doesn't work
- Eurocombi A23 MFFI - The hot water is lukewarm
- Microgenus HE Combi Boiler - Fault A01 faulty PCB replacement 65103422 (Replaces 65102571)
Baxi
- Combi 80e - faulty hot water THERMISTER
- Combi 80e - faulty gas valve 5107339
- Precision+ Faulty Control & Fan Assembly Part No 7618106
- Duo-Tec Combi HE - Faulty pressure sensor 5114748
- Combi 80e - Domestic hot water diaphragm
- Solo 2 PF50 - PCB replacement
- Combi 105HE - loosing pressure fast
Biasi
- 24S - No hot water. Faulty diaphragm BI1011102
- M90E.24S - BI1001117 temperature probe replacement
- M96.24SM/C2 - PCB replacement BI12015100 (replaces BI1715105)
- M90.24S - BI1036102 24kw air pressure switch replacement
- 24S - Timer replacement
- Riva Compact HE - boiler timer doesn't work
Chaffoteaux
Electroheat PLC
Ethos
Ferroli
- DOMIcondense HE26C - main heat exchanger 39837660
- Modena F24 Pump Assembly 39808300
- F 30 - hot water but no heating
Glowworm
- Betacom c24 - Faulty Diverter valve - 0020064049
- Betacom 24 - leaking Glowworm Water Cock 22mm 0020027544
- Betacom 24c - PCB 0020061654
- Flexicom 18HX - F70 fault code. Faulty display
- Xtrafast - faulty timer 57245
- 35CI - Faulty timer 2000800089
- British Gas 330 - Fault code F5
- 38cxi - Filling Loop 2000802600 replacement
- 24 CXI is constantly leaking from many places
- 30SXI - repair boiler loosing pressure
- Ultimate 40FF
- 30 CXI - fault F13
- Betacom 30C - hot water is intermittent
- Xtramax HE
Halstead
Heat Lline
- CaprizPlus 28a - Faulty Diverter Valve Actuator Motor 3003200039
- Capriz 28 - faulty PCB (3003202166)
- Capriz 28 - hot water is lukewarm - diverter valve service kit 3003202082
- Vizo 24 - Faulty Diverter valve 3003200017
Ideal
- Isar HE24 - Faulty Diverter valve (173624)
- Mini C24, C28, C32 Faulty Gas Valve 172611,173220, BI1193105
- Logic 30 - Faulty timer 204839
- Icos HE24 - leaking automatic air vent valve 170988
- isar 24 HE - PCB replacement
- Elan RS30 - Boiler is not firing up
Keston
- P55 - leaking flue exhaust tube Kit C17233001 replaces C17224001
- Qudos 28S - Faulty fan (Q10S301001) Error code E28
- C55 - intermittent fault. Faulty PCB C17401000
- C40 - Low water pressure fault b26
Main
- combi 25eco Faulty pressure relief valve 248056
- Combi 24 HE - Intermittent hot water. Faulty diaphragm 5111137
- Mersey Super multipoint water heater - faulty automatic valve 2106378
- Combi 24 HE - Radiators are getting hot when hot water tap is opened. Faulty Hydraulic Venturi 24805
- Combi 24 HE - Hot water is lukewarm faulty water pressure switch 248063
- Main Combi 25 Eco Elite - makes a loud noise when igniting or goes to a lockout Baxi Ingition/Ionisa
- Combi 24 HE - boiler often goes to an ignition lockout
- Combi 24 HE - Hot water is lukewarm
- Combi 24 HE - Flame failure light on boiler
- System HE - Flame goes off after 10 seconds.
Myson
Nibe
Potterton
- Gold 28HE A - faulty Ignition electrode 5114702 or 720222801
- Prima F - faulty PCB 407677
- Prforma 24 - intermittent clicking and hot water
- Performa 30HE - faulty PCB 5112380
- Suprima 80 HE - Faulty PCB (SM10501U)
- Suprima - Faulty fan 40958801
- Profile - faulty thermostat 907729
- Housewarmer 45 - Faulty PCB replacement (407725)
- Performa 24 - faulty thermistor (NTC temperature sensor 5108265)
- Suprima 60 - faulty PCB 5111603 (replaces 408850)
- Promax Combi 28 HE A - Faulty diverter valve and motor
- Puma 80e - faulty diverter valve replacement (8929899)
- Suprima 40,70 - faulty gas valve 402550 (VK4105E 1007)
- Profile 100e - faulty PCB 407677
- Netaheat 10/16 Electronic - Air pressure switch replacement 642204
- Performa 30 HE - DHW diaphragm replacement
- Performa 24 Eco HE - Air pressure switch 5137532
- Combi 80 - Overheat lockout after closing a hot water tap
- Profile 100e - faulty fan 409569
- Combi 80 - Loosing a lot of pressure
- Puma 80e doesn't have any lights on a control board
- Suprima 40L - Ignition lockout, no spark occurring
- Performa 24 - goes to overheat lock out
- Netaheat Profile 50e - faulty PCB
- Powermax HE - e.01 fault code
- Netaheat Profile 50e - doesn't fire up
- Suprima 40L - lockout twice a day
- Prima 50C - Boiler is not firing but pilot light is on
- Prima 50C - Boiler goes to lockout 2 times a day
Remeha
Saunier Duval
Vaillant
- ecoTec Plus 937 - Hot water pump 0020039793
- ecoTec Plus 637 F.75 Fault Pump replacement 0020025042
- Turbomax Plus 837E F.28 Gas valve 114189 Original Sigma 845
- ecoTec plus 831 - F.75 error message - faulty expansion vessel (181051)
- EcoTec plus 637 F.32 Faulty fan 193593
- ecotec Plus 824 - Fault F.75 - Faulty expansion vessel (181051)
- ecoTec plus 837 - Diverter valve 0020132682 leaking
- ecoTec pro24 - fault F62 PCB 0020132764 or Gas valve replacement
- Thermocompact VC GB 142 EH - wiring diagram
- ecoTec plus 824 - Con - display fault PCB (0020132764)
- TurboMax 242E - No hot water, faulty diverter valve 011289
- TurboMAX Plus 824E - faulty fan replacement 0020020008 (old: 190272)
- TurboMax Plus 828E - faulty Printed circuit board PCB 130806
- TurboMax Plus 828E - Faulty pressure gauge 101271
- Thermocompact 628E - Combustion gases testing point plug 139472 replacement
- ecoTec plus - filling loop replacement
- ecoTec plus 824 - Diverter valve replacement 0020132682
- ecoTec Plus 831 combi boiler - flexi connector replacement
- ecoTec old boilers - Vaillant Gasket Seal 0020038679
- ecoTec plus 824 boiler - F.20 fault code
- ecoTec plus 824 boiler - fault F.75 (no heating and hot water)
- Thermocompact VC GB 242 EH - gas valve fault
- ecoTec plus 637 - PCB replacement
- ecoTec plus - pump replacement
- combiCompact VCW - No heating but hot water is working
- ecoTec pro 24,28 plus 824,831 - error code F.75 faulty pump (178983)
- TURBOmax Plus 824E - broken filling valve
- TURBOmax Plus 824E - no heating, no hot water
- Boiler goes to lockout after 2 hours after reset
Viessmann
- Vitodens 100 W WB1B - 7828718 Ignition Ionization Electrode fault F4
- Vitodens 100 W Compact - Outer case fixing clips
Vokera
Worcester
- Greenstar 30CDI Combi - intermittent hot water
- 532/i - Error C6, Faulty fan 87161160670; 87172044530; 8716118443
- Highflow 400 RSF - No heating. Faulty diverter valve (87161207390)
- Worcester Greenstar Junior 24i, 28i - Faulty MT10 Single Channel Mechanical Boiler Clock (7716192036
- 24i - broken temperature control knob 87161410440
- 24CDi RSF Combi - Faulty fan 8716120034
- Greenstar 30CDI Conventional boiler - F0 error - full boiler reset
- Greenstar Ri 24 - Faulty PCB replacement 87186871640
- Highflow 400 ELECTRONIC - Hot water temperature flactuation
- Greenstar R 25HE - C1 error, faulty fan 87172043730
- 24CDI RSF Combi - Pump replacement 87161431080
- 24i standard efficiency - 77161920020 cdi-mechanical timer replacement
- 24CDI - Worcester 87161202820 Fan Assembly replacement
- Greenstar 24i Junior - Faulty Worcester Fan Assembly 87161160670
- 24CDi RSF Combi - Faulty diverter valve diaphragm 87161405530
- Greenstar 24i Junior - Leaking, no heating
- 24i Junior - flashes once a second
- Greenstar 24i Junior - makes a very loud noise and stops working
- 28i Junior - Pump replacement
- Greenstar 24i Junior - is leaking from various places under the boiler
- 24i Junior - flashes 4 times per second
- Greenstar 30CDI Combi C6 fault code repair
- Greenstar 24i Junior - timer is not working
Taps
Armitage Shanks
Grohe
Hansgrohe
Ideal
Ideal Standard/Armitage Shanks
Mayfair
Phoenix
S960025NU Cartridge Replacement
Space Heaters
Baxi
Multiglow
Bathstore Thermostatic Cartridge
Servicing Guide
Pumps
Grundfos
Thermal Store Cylinders
Pulsacoil
- 2000 - faulty T1 thermistor GT153
- A-class - Burnt relay and base
- 3 - faulty pump replacement - Grundfos 15/50 Pump for Gledhill Units XB004
- A-class APA4200 - faulty Gledhill MIP098 Relay Retro Fit Kit
- 2000 - Gledhill GT153 Boilermate/Systemate/ Gulfstream Hot water Sensor replacement
- A-Class - 4 Pin overheat sensor GT199 replacement
- 2000 - Pulsa Coil 2000 PCB GT152 replacement
- 3 - Gledhill Relay XB321 replacement
- 2000 - Grundfos 15/50 Pump XB004 replacement
- A-CLASS APA4180 - Faulty OMRON RELAY & BASE XB298
- 2000 - Hot water temperature flactuation
- 2000 Electric Thermal Store - boiling hot, condensation on the ceiling
- III - intermittent hot water
- 2000 - Electric Thermal Store
Underfloor Heating
PolyPlumb
Toilets
Geberit
Grohe
- Old Style Pneumatic Flush Valve and a Button
- Concealed toilet flush repair
- 20.03.44 - flash valve is letting by
Hot Water Cylinders
Dimplex
Megaflow
- - No hot water
- Safety discharge pipe is dripping
- The cylinder is not heating up Immersion Heater replacement
Santon
Gas Safety Inspection
Gas Flue Analysers
Gas Hobs
AGA
Neff
Ariston Microgenus 32HE MFFI E34 error code Faulty fan (65102567)
Ariston Microgenus 32HE MFFI - no heating or hot water
- The boiler pump is working but after 5 seconds the boiler goes into a lock out with an error code E34.
- Open the boiler casing and reset the boiler
- Check the voltage to the boiler fan.
- Check resistance between neutral and live terminals on the fan. A working fan should have around 40 Ohms resistance. A faulty fan will have around 2 Ohms.
- If voltage to the fan is 240V then replace the fan
- The part number is 65102567 for 28kw model
- Completely isolate the electricity to the boiler when replacing the fan
< Go Back | 2017-03-02 |
Ariston Microcombi 23 MFFI - Boiler flue replacement
- ARISTON FLUE KIT (HORIZONTAL) STANDARD EFFICIENCY 3318000
< Go Back | 2015-05-23 |
Ariston Microgenus 23 MFFI - Faulty PCB 65101732
Ariston Microgenus 23 MFFI combi boiler has an intermittent heating and hot water (normally in the evenings)
- Boiler doesn't start and needs to be switched on and off several times before it fires up
- Pump is running
- Fan doesn't run
- There is no power to the fan
- Replace PCB - the part number is ARISTON PCB (CMP3-MCU HS MI/FFI) 65101732 (REPLACES 996163, 998642, 998947) (MICROGENUS 23 & 27)
< Go Back | 2014-10-17 |
Ariston Microcombi 23 MFFI - Ariston Low Water Pressure Switch 995903
Ariston Microcombi 23 MFFI combi boiler doesn't fire up, no warning ligth and it doesn't reset
- The pump is not running
- The fan is not running
- Reset button doesn't do anything
- Remove 2 grey wires from Low water pressure switch inside the boiler and connect them bypassing the switch
- If boiler fires up then replace the part: Ariston Low water pressure switch 995903
< Go Back | 2014-06-12 |
Ariston Microcombi 23 MFFI - PCB replacement 65100248
Ariston Microcombi 23 MFFI boiler doesn't work
- No heating or hot water are working
- The power light and the central heating light on the front panel are on
- Boiler pressure is normal and the low pressure switch is not faulty
- If the pump doesn't run then replace PCB
- replacement part is: Ariston 65100248 PRINTED CIRCUIT BOARD
- Replaces 999952 (old part number)
< Go Back | 2014-06-11 |
Ariston Microgenus 23 MFFI - Pump fault
Ariston Microgenus 23 MFFI - no heating and hot water. A red pump fault indicator is lit on a dash board.
- The pump replacement part number is 996614
< Go Back | 2014-01-02 |
Ariston Microgenus 23 MFFI - PCB problem. Knocking and rattling noise coming from the gas valve.
Ariston Microgenus 23 MFFI - Knocking and rattling noise coming from the gas valve when hot water is running but apart from that the boiler is working fine.
- This is a PCB fault.
- Replacement part number is 65101732 (replaces 996163, 998642, 998947) designed to fit an Ariston Microgenus 23 and 27 MFFI CE gas combination boiler.
- The part number 65103422 (REPLACES 65102571) (Microgenus HE 24,28 & 32) - doesn't work for this boiler
< Go Back | 2013-11-09 |
Ariston Microgenus HE Combi Boiler - Fault A03
Ariston Microgenus HE combi boiler displays fault code A03 and doesn't reset. After the reset button pressed the error code stays the same and the pump starts running.
- A03 fault code means that the flow temperature exceeds 103oC.
- If pump is working fine then it's likely that the problem is an overheat stat.
- Remove the left side panel for access.
- Put a wire bridge between overheat stat contacts and if the boiler starts working then the overheat stat need to be replaced.
- In my case when I swapped the contacts to the overheat stat the boiler started to work fine.
< Go Back | 2013-08-20 |
Ariston Eurocombi A23 MFFI - No hot water but heating is working
The boiler doesn’t produce any hot water at all but the temperature on a dashboard remains at 80oC.
- The problem is hot water temperature probe is faulty
- Open the boiler cover and pull the connection to the thermistor out
- The thermistor is located on a diverter valve on the right hand side of the boiler
- Once you pulled it out, open the hot water tap. The boiler should start working.
- Don’t leave it working this way because it will go to overheat lock out after some time as it doesn't know the water temperature at the moment
- To fix the boiler you need to isolate flow and return pipes and drain the boiler in order to replace the thermistor
- The part number for replacement is 998458
< Go Back | 2013-06-27 |
Ariston MicroGenus II 28 MFFI - mechanical timer doesn't work
Ariston MicroGenus II 28 MFFI mechanical clock doesn't work on timer. If you can hear the clock ticking but it very stiff to turn or you can not hear its ticking then the clock need replacement. Also do the following check. Set the time on the clock and remember it. Then check the time after one hour. If the clock didn't move then its faulty. Before replacing the clock isolate the electrical supply to the boiler by removing the fuse from the boiler switch. The part number is 999599 and you can order it from here. To replace this part you don't need a gas engineer.
Ariston MicroGenus II 28 MFFI manual: PDF
< Go Back | 2013-03-20 |
Ariston Eurocombi A23 MFFI - The hot water is lukewarm
The water from a hot tap is lukewarm and keeps fluctuating. First of all we need to check the burner pressure of the boiler. Remove the from cover and connect the U-gauge to a P2 test point on a gas valve. Open the hot tap and with the boiler on check the burner pressure. It should be 11 mbar. If it is then we need to test the hot water thermistor. Unplug the wire and measure resistance between two connectors. It should be 12 kOhms at 12°C. If it is then we need to test the plate heat exchanger. Open a hot tap and touch the heat exchanger. If within 20 seconds it gets scalding hot then its blocked and need cleaning or replacing. The part number for the heat exchanger is 571646 and can be ordered from here.Â
Boiler manual: PDF
< Go Back | 2013-02-28 |
Ariston Microgenus HE Combi Boiler - Fault A01 faulty PCB replacement 65103422 (Replaces 65102571)
Ariston Microgenus HE Combi Boiler works for 7 seconds and then goes to a lock-out with a fault code A01 on a screen
- Turn the central heating or hot water on
- remove the front cover and watch the spark electrodes
- If they continue to spark after the flame is present then check the flame sensing electrode (the left hand side one)
- if it looks intact then check the wire from it to PCB for continuity with a multimeter
- If there is a continuity then replace a PCB
- The replacement part number is ARISTON PCB (PRINTED CIRCUIT BOARD) 65103422 (REPLACES 65102571) (MICROGENUS HE 24,28 & 32)
< Go Back | 2013-01-27 |