Switch to mobile site
Loading

Maintenance and Service

Baxi

Click to open/close The Main Menu

Showers

Aqualisa

Armitage Shanks

Bristan

Crosswater

Crosswater

Grohe

HUB-001A-WAX Vado Thermostatic Cartridge

Hansgrohe

Hudson Reed

IB

Mira

Porcelanosa

S960134NU Thermostatic Cartridge

Sirrus Rothwell R995 Antique Shower

Swadling

Trevi

Triton

Triton

Ultra

Vado

Vola

Boilers

Alfa Laval

Alpha

Ariston

Baxi

Biasi

Chaffoteaux

Electroheat PLC

Ethos

Ferroli

Glowworm

Halstead

Heat Lline

Ideal

Keston

Main

Myson

Nibe

Potterton

Remeha

Saunier Duval

Vaillant

Viessmann

Vokera

Worcester

Taps

Armitage Shanks

Grohe

Hansgrohe

Ideal

Ideal Standard/Armitage Shanks

Mayfair

Phoenix

S960025NU Cartridge Replacement

Space Heaters

Baxi

Multiglow

Bathstore Thermostatic Cartridge

Servicing Guide

Pumps

Grundfos

Thermal Store Cylinders

Pulsacoil

Underfloor Heating

PolyPlumb

Toilets

Geberit

Grohe

Hot Water Cylinders

Dimplex

Megaflow

Santon

Gas Safety Inspection

Gas Flue Analysers

Gas Hobs

AGA

Neff

 

Baxi Combi 80e - faulty hot water THERMISTER

Baxi Combi 80e - faulty  THERMISTER TEMPERATURE SENSOR 5108265 WAS 247394

Central heating is working fine but the hot water is cutting off from time to time and the light flashes next to the crossed over hot water tap sign and then goes back to the temperature lights. This fault indicates a fault with a hot water temperature sensor which is located next to the plate hot water heat exchanger on the right hand side. You will need to isolate the water supply to the boiler and open a hot water tap to replace this part.

 

< Go Back2019-06-29

Baxi Combi 80e - faulty gas valve 5107339

Baxi Combi 80e - faulty gas valve 5107339

GC.No. 4707506

Hot water is intermittent. It goes hot and then runs cold and hot again. The boiler makes clicking noises and the lights on a control panel randomly flashing from time to time. It seems like a PCB Fault but actually it is a harness or a gas valve problem. If you disconnect the gas valve wires there should be a resistance between top 2 pins around 1.5lOhms and bottom 2 pins around 2.5kOhms. Between top and the bottom around 4kOhms. If there is no resistance between any of them then replace the gas valve.

< Go Back2019-06-16

Baxi Precision+ Faulty Control & Fan Assembly Part No 7618106

Baxi Precision+ boiler doesn't work. Orange light fluahes 4 times.

  • Check if the fan is spinning while the warning light is flushing.
  • In not then replace Control & Fan Assembly Part No 7618106
< Go Back2018-07-14

Baxi Duo-Tec Combi HE - Faulty pressure sensor 5114748

Boiler displays error code E1

Replace or clean the pressure switch 5114748

< Go Back2016-03-25

Baxi Combi 80e - Domestic hot water diaphragm

Baxi Combi 80e - Domestic hot water diaphragm is perished and need replacement. The heating is working fine but there is no hot water.

  • Open a hot water tap and look at the flow sensor pin should move forward and press the microswitch to fire up the boiler
  • If the pin doesn't move then diaphragm need replacement
  • The replacement part is 248066
< Go Back2013-11-09

Baxi Solo 2 PF50 - PCB replacement

Baxi Solo 2 PF 50 boiler doesn't work.

Fault 1: The fan is running, the gas valve is opened but there is no spark occurring occasionally.

Fault 2: The boiler fan is running howerver the PCB is making a constant clicking sound and boiler doesn't ignite. If air pressure switch tubes are disconnected teh noise stops but boiler still does not ignite.

< Go Back2013-10-27

Baxi Combi 105HE - loosing pressure fast

Baxi Combi 105HE boiler is loosing pressure very fast. First of all check that the filling loop which supposed to top up the central heating system with water was closed. Then you should check the expansion vessel charge it should be around 1bar. If there is no charge or water is coming when you pressed the nipple then replace or recharge it with the pump up to 1.5 bar. Top up the system up to 2 bar and watch the pressure discharge pipe outside the property if its constantly dripping or pouring water then Pressure Relief Valve have to be replaced. The part number is 248056 and you can order it from here. To replace this part you don't need a gas engineer.

Baxi Combi 105HE manual: PDF

< Go Back2013-03-16

Baxi Brazilia F8S

Balanced flue gas wall heater Baxi Brazilia F8S brocken control knob. For this particular model F8S you will need a long version of the control knob. The replacement part number is Baxi 234643 control knob assembly. To replace this part you don't need a gas engineer. In order to fit the replacement part correctly simply remove the casing by pulling it upwards. You can order it from here.

Wall heater manual: PDF