Halstead
Click to open/close The Main Menu
Showers
Aqualisa
- Colt - Dripping shower cartridge replacement Aqualisa Cartridge Grey 022801
- Midas 100 Faulty Thermostatic Cartridge 518101
- Aquavalve 609 thermostatic
- Aquavalve 409 manual shower valve is dripping
Armitage Shanks
Bristan
- Prism - No water. Faulty Flow Diverter Cartridge (APT 04895)
- CART18 Faulty Push-In Thermostatic Cartridge 06734B - No hot water
- Concealed thermostatic valve - thermostatic cartridge 00650410
- Chill Concealed 3 Control Shower Valve - Faulty Thermostatic Cartridge (Threaded) - 00622415
Crosswater
- flow cartridge (x2A071N) leaking
- CP0000250 Thermostatic Cartridge Failure
- Belgravia Exposed Valve not regulating water temperature correctly
- minimalistic shower bar - Crosswater Flow Valve replacement (CROSS-CG1210FA1)
- SOL - Thermostatic cartridge replacement
- SME-029 Thermostatic shower - Temperature and pressure problem
Crosswater
- flow cartridge (x2A071N) leaking
- CP0000250 Thermostatic Cartridge Failure
- Belgravia Exposed Valve not regulating water temperature correctly
- minimalistic shower bar - Crosswater Flow Valve replacement (CROSS-CG1210FA1)
- SOL - Thermostatic cartridge replacement
- SME-029 Thermostatic shower - Temperature and pressure problem
Grohe
- 47600000: Temperature and Flow Rate Problems
- faulty Kohler 78913 Thermostatic 3/4 inch Cartridge
- Sentosa - Water is constantly leaking from a bath filler
- Auto 2000 - temperature flactuation
HUB-001A-WAX Vado Thermostatic Cartridge
Hansgrohe
Hudson Reed
- Thermostatic Cartridge for SNINASF CEL-001A-WAX Ultra, Hudson Reed, Vado, Crosswater
- Ultra Hudson Reed SA30049 faulty Thermostatic Cartridge
- Traditional Dual Exposed Thermostatic Shower Valve ITY309 - Thermostatic cartridge replacement DC70T
- Kia/Jule A3010 - water is not getting hot
IB
- Rubinetterie - faulty thermostatic cartridge replacement CP0000250
- Crosswater - Non Return Valve IBNRV replacement
- Rubinetterie - Thermostat does not turn
- Hot water is lukewarm
Mira
- Discovery - Constantly leaking from a shower head (Flow Control 1.1609.042.2)
- Discovery shower turn on and off control knob is brocken
- 723 - thermostatic cartridge replacement (High pressure 902.70)
- Realm post 1993 - dripping from a shower head
- Crescent Cheltenham
Porcelanosa
- Eurohub V54001A - faulty Thermostatic cartridge SH-U960016AA
- Noken NK - CICE France OPTIMA 40 TH F Thermostatic Cartridge
- System Pool Tina shower valve temperature control is too stiff
S960134NU Thermostatic Cartridge
Sirrus Rothwell R995 Antique Shower
Swadling
Trevi
- E4705AA Trevi wall outlet assembly replacement
- THERM HP A2443 (314) Wall Mounted Thermostatic Bath/Shower Mixer - Flow cartridge replacement
- No water coming out when the shower is opened
- Therm MK2 - no hot water
Triton
- Thermostatic cartridge 83307770 Replacement Tips
- Combi HP - thermostatic shower water is too cold
- Dart 3 Thermostatic Cartridge Service Kit 8
- 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water
- Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120
- Unichrome Tees temperature control is too stiff
Triton
- Thermostatic cartridge 83307770 Replacement Tips
- Combi HP - thermostatic shower water is too cold
- Dart 3 Thermostatic Cartridge Service Kit 8
- 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water
- Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120
- Unichrome Tees temperature control is too stiff
Ultra
Vado
Vola
Boilers
Alfa Laval
Alpha
- CD35C - No hot water, heating start working when hot tap is opened
- CB28x - Red and Amber light are on - Faulty PCB (1.017118)
- CD50 - no lights - Faulty PCB (1.027267)
Ariston
- Microgenus 32HE MFFI E34 error code Faulty fan (65102567)
- Microcombi 23 MFFI - Boiler flue replacement
- Microgenus 23 MFFI - Faulty PCB 65101732
- Microcombi 23 MFFI - Ariston Low Water Pressure Switch 995903
- Microcombi 23 MFFI - PCB replacement 65100248
- Microgenus 23 MFFI - Pump fault
- Microgenus 23 MFFI - PCB problem. Knocking and rattling noise coming from the gas valve.
- Microgenus HE Combi Boiler - Fault A03
- Eurocombi A23 MFFI - No hot water but heating is working
- MicroGenus II 28 MFFI - mechanical timer doesn't work
- Eurocombi A23 MFFI - The hot water is lukewarm
- Microgenus HE Combi Boiler - Fault A01 faulty PCB replacement 65103422 (Replaces 65102571)
Baxi
- Combi 80e - faulty hot water THERMISTER
- Combi 80e - faulty gas valve 5107339
- Precision+ Faulty Control & Fan Assembly Part No 7618106
- Duo-Tec Combi HE - Faulty pressure sensor 5114748
- Combi 80e - Domestic hot water diaphragm
- Solo 2 PF50 - PCB replacement
- Combi 105HE - loosing pressure fast
Biasi
- 24S - No hot water. Faulty diaphragm BI1011102
- M90E.24S - BI1001117 temperature probe replacement
- M96.24SM/C2 - PCB replacement BI12015100 (replaces BI1715105)
- M90.24S - BI1036102 24kw air pressure switch replacement
- 24S - Timer replacement
- Riva Compact HE - boiler timer doesn't work
Chaffoteaux
Electroheat PLC
Ethos
Ferroli
- DOMIcondense HE26C - main heat exchanger 39837660
- Modena F24 Pump Assembly 39808300
- F 30 - hot water but no heating
Glowworm
- Betacom c24 - Faulty Diverter valve - 0020064049
- Betacom 24 - leaking Glowworm Water Cock 22mm 0020027544
- Betacom 24c - PCB 0020061654
- Flexicom 18HX - F70 fault code. Faulty display
- Xtrafast - faulty timer 57245
- 35CI - Faulty timer 2000800089
- British Gas 330 - Fault code F5
- 38cxi - Filling Loop 2000802600 replacement
- 24 CXI is constantly leaking from many places
- 30SXI - repair boiler loosing pressure
- Ultimate 40FF
- 30 CXI - fault F13
- Betacom 30C - hot water is intermittent
- Xtramax HE
Halstead
Heat Lline
- CaprizPlus 28a - Faulty Diverter Valve Actuator Motor 3003200039
- Capriz 28 - faulty PCB (3003202166)
- Capriz 28 - hot water is lukewarm - diverter valve service kit 3003202082
- Vizo 24 - Faulty Diverter valve 3003200017
Ideal
- Isar HE24 - Faulty Diverter valve (173624)
- Mini C24, C28, C32 Faulty Gas Valve 172611,173220, BI1193105
- Logic 30 - Faulty timer 204839
- Icos HE24 - leaking automatic air vent valve 170988
- isar 24 HE - PCB replacement
- Elan RS30 - Boiler is not firing up
Keston
- P55 - leaking flue exhaust tube Kit C17233001 replaces C17224001
- Qudos 28S - Faulty fan (Q10S301001) Error code E28
- C55 - intermittent fault. Faulty PCB C17401000
- C40 - Low water pressure fault b26
Main
- combi 25eco Faulty pressure relief valve 248056
- Combi 24 HE - Intermittent hot water. Faulty diaphragm 5111137
- Mersey Super multipoint water heater - faulty automatic valve 2106378
- Combi 24 HE - Radiators are getting hot when hot water tap is opened. Faulty Hydraulic Venturi 24805
- Combi 24 HE - Hot water is lukewarm faulty water pressure switch 248063
- Main Combi 25 Eco Elite - makes a loud noise when igniting or goes to a lockout Baxi Ingition/Ionisa
- Combi 24 HE - boiler often goes to an ignition lockout
- Combi 24 HE - Hot water is lukewarm
- Combi 24 HE - Flame failure light on boiler
- System HE - Flame goes off after 10 seconds.
Myson
Nibe
Potterton
- Gold 28HE A - faulty Ignition electrode 5114702 or 720222801
- Prima F - faulty PCB 407677
- Prforma 24 - intermittent clicking and hot water
- Performa 30HE - faulty PCB 5112380
- Suprima 80 HE - Faulty PCB (SM10501U)
- Suprima - Faulty fan 40958801
- Profile - faulty thermostat 907729
- Housewarmer 45 - Faulty PCB replacement (407725)
- Performa 24 - faulty thermistor (NTC temperature sensor 5108265)
- Suprima 60 - faulty PCB 5111603 (replaces 408850)
- Promax Combi 28 HE A - Faulty diverter valve and motor
- Puma 80e - faulty diverter valve replacement (8929899)
- Suprima 40,70 - faulty gas valve 402550 (VK4105E 1007)
- Profile 100e - faulty PCB 407677
- Netaheat 10/16 Electronic - Air pressure switch replacement 642204
- Performa 30 HE - DHW diaphragm replacement
- Performa 24 Eco HE - Air pressure switch 5137532
- Combi 80 - Overheat lockout after closing a hot water tap
- Profile 100e - faulty fan 409569
- Combi 80 - Loosing a lot of pressure
- Puma 80e doesn't have any lights on a control board
- Suprima 40L - Ignition lockout, no spark occurring
- Performa 24 - goes to overheat lock out
- Netaheat Profile 50e - faulty PCB
- Powermax HE - e.01 fault code
- Netaheat Profile 50e - doesn't fire up
- Suprima 40L - lockout twice a day
- Prima 50C - Boiler is not firing but pilot light is on
- Prima 50C - Boiler goes to lockout 2 times a day
Remeha
Saunier Duval
Vaillant
- ecoTec Plus 937 - Hot water pump 0020039793
- ecoTec Plus 637 F.75 Fault Pump replacement 0020025042
- Turbomax Plus 837E F.28 Gas valve 114189 Original Sigma 845
- ecoTec plus 831 - F.75 error message - faulty expansion vessel (181051)
- EcoTec plus 637 F.32 Faulty fan 193593
- ecotec Plus 824 - Fault F.75 - Faulty expansion vessel (181051)
- ecoTec plus 837 - Diverter valve 0020132682 leaking
- ecoTec pro24 - fault F62 PCB 0020132764 or Gas valve replacement
- Thermocompact VC GB 142 EH - wiring diagram
- ecoTec plus 824 - Con - display fault PCB (0020132764)
- TurboMax 242E - No hot water, faulty diverter valve 011289
- TurboMAX Plus 824E - faulty fan replacement 0020020008 (old: 190272)
- TurboMax Plus 828E - faulty Printed circuit board PCB 130806
- TurboMax Plus 828E - Faulty pressure gauge 101271
- Thermocompact 628E - Combustion gases testing point plug 139472 replacement
- ecoTec plus - filling loop replacement
- ecoTec plus 824 - Diverter valve replacement 0020132682
- ecoTec Plus 831 combi boiler - flexi connector replacement
- ecoTec old boilers - Vaillant Gasket Seal 0020038679
- ecoTec plus 824 boiler - F.20 fault code
- ecoTec plus 824 boiler - fault F.75 (no heating and hot water)
- Thermocompact VC GB 242 EH - gas valve fault
- ecoTec plus 637 - PCB replacement
- ecoTec plus - pump replacement
- combiCompact VCW - No heating but hot water is working
- ecoTec pro 24,28 plus 824,831 - error code F.75 faulty pump (178983)
- TURBOmax Plus 824E - broken filling valve
- TURBOmax Plus 824E - no heating, no hot water
- Boiler goes to lockout after 2 hours after reset
Viessmann
- Vitodens 100 W WB1B - 7828718 Ignition Ionization Electrode fault F4
- Vitodens 100 W Compact - Outer case fixing clips
Vokera
Worcester
- Greenstar 30CDI Combi - intermittent hot water
- 532/i - Error C6, Faulty fan 87161160670; 87172044530; 8716118443
- Highflow 400 RSF - No heating. Faulty diverter valve (87161207390)
- Worcester Greenstar Junior 24i, 28i - Faulty MT10 Single Channel Mechanical Boiler Clock (7716192036
- 24i - broken temperature control knob 87161410440
- 24CDi RSF Combi - Faulty fan 8716120034
- Greenstar 30CDI Conventional boiler - F0 error - full boiler reset
- Greenstar Ri 24 - Faulty PCB replacement 87186871640
- Highflow 400 ELECTRONIC - Hot water temperature flactuation
- Greenstar R 25HE - C1 error, faulty fan 87172043730
- 24CDI RSF Combi - Pump replacement 87161431080
- 24i standard efficiency - 77161920020 cdi-mechanical timer replacement
- 24CDI - Worcester 87161202820 Fan Assembly replacement
- Greenstar 24i Junior - Faulty Worcester Fan Assembly 87161160670
- 24CDi RSF Combi - Faulty diverter valve diaphragm 87161405530
- Greenstar 24i Junior - Leaking, no heating
- 24i Junior - flashes once a second
- Greenstar 24i Junior - makes a very loud noise and stops working
- 28i Junior - Pump replacement
- Greenstar 24i Junior - is leaking from various places under the boiler
- 24i Junior - flashes 4 times per second
- Greenstar 30CDI Combi C6 fault code repair
- Greenstar 24i Junior - timer is not working
Taps
Armitage Shanks
Grohe
Hansgrohe
Ideal
Ideal Standard/Armitage Shanks
Mayfair
Phoenix
S960025NU Cartridge Replacement
Space Heaters
Baxi
Multiglow
Bathstore Thermostatic Cartridge
Servicing Guide
Pumps
Grundfos
Thermal Store Cylinders
Pulsacoil
- 2000 - faulty T1 thermistor GT153
- A-class - Burnt relay and base
- 3 - faulty pump replacement - Grundfos 15/50 Pump for Gledhill Units XB004
- A-class APA4200 - faulty Gledhill MIP098 Relay Retro Fit Kit
- 2000 - Gledhill GT153 Boilermate/Systemate/ Gulfstream Hot water Sensor replacement
- A-Class - 4 Pin overheat sensor GT199 replacement
- 2000 - Pulsa Coil 2000 PCB GT152 replacement
- 3 - Gledhill Relay XB321 replacement
- 2000 - Grundfos 15/50 Pump XB004 replacement
- A-CLASS APA4180 - Faulty OMRON RELAY & BASE XB298
- 2000 - Hot water temperature flactuation
- 2000 Electric Thermal Store - boiling hot, condensation on the ceiling
- III - intermittent hot water
- 2000 - Electric Thermal Store
Underfloor Heating
PolyPlumb
Toilets
Geberit
Grohe
- Old Style Pneumatic Flush Valve and a Button
- Concealed toilet flush repair
- 20.03.44 - flash valve is letting by
Hot Water Cylinders
Dimplex
Megaflow
- - No hot water
- Safety discharge pipe is dripping
- The cylinder is not heating up Immersion Heater replacement
Santon
Gas Safety Inspection
Gas Flue Analysers
Gas Hobs
AGA
Neff
Halstead Ace High - faulty hot water micro-switch 500593
A boiler went to overheat lock out once a month when hot water was on. Then it began happening more often until it stopped producing any hot water at all. Heating was working fine.
Reason and solution:
- Water was leaking through a domestic hot water spindle of a flow switch
- This water went to a hot water micro-switch
- It made the micro-switch to stuck in open position causing overheating
- When water dried out the boiler came back to normal
- It was happening until the micro-switch completely get broken
- To fix - need to replace a hot water micro-switch
- The part number is 500593
< Go Back | 2013-06-12 |