Switch to mobile site
Loading

Maintenance and Service

Heat Lline

Click to open/close The Main Menu

Showers

Aqualisa

Armitage Shanks

Bristan

Crosswater

Crosswater

Grohe

HUB-001A-WAX Vado Thermostatic Cartridge

Hansgrohe

Hudson Reed

IB

Mira

Porcelanosa

S960134NU Thermostatic Cartridge

Sirrus Rothwell R995 Antique Shower

Swadling

Trevi

Triton

Triton

Ultra

Vado

Vola

Boilers

Alfa Laval

Alpha

Ariston

Baxi

Biasi

Chaffoteaux

Electroheat PLC

Ethos

Ferroli

Glowworm

Halstead

Heat Lline

Ideal

Keston

Main

Myson

Nibe

Potterton

Remeha

Saunier Duval

Vaillant

Viessmann

Vokera

Worcester

Taps

Armitage Shanks

Grohe

Hansgrohe

Ideal

Ideal Standard/Armitage Shanks

Mayfair

Phoenix

S960025NU Cartridge Replacement

Space Heaters

Baxi

Multiglow

Bathstore Thermostatic Cartridge

Servicing Guide

Pumps

Grundfos

Thermal Store Cylinders

Pulsacoil

Underfloor Heating

PolyPlumb

Toilets

Geberit

Grohe

Hot Water Cylinders

Dimplex

Megaflow

Santon

Gas Safety Inspection

Gas Flue Analysers

Gas Hobs

AGA

Neff

 

Heat Lline CaprizPlus 28a - Faulty Diverter Valve Actuator Motor 3003200039

Fault description

Boiler does not produce any hot water. When hot water tap opened the boiler works but radiators getting hot instead.

Cause of the problem

Most likely cause is a faulty diverter valve or diverter valve actuator. To check which one disconnect the diverter actuator from the valve and open the hot water. If there is power to the diverter vale but the spindle isn't moving the replace the actuator

Replacement part number

Diverter Valve Actuator Motor 3003200039

 

< Go Back2020-01-18

Heat Lline Capriz 28 - faulty PCB (3003202166)

Heat line Capriz 28 Combination boiler goes into ignition lockout with a red flame light on the front panel after an attempt to ignite.

If the boiler is trying to ignite but the flame doesn't stay the the flame sensing electrode or PCB flame rectification device is faulty. Check the flame sensing electrode's position and continuity (use multi-meter) from the tip to the connection port on PCB. If there is a continuity then replace the Pcb

The part number for the PCB is 3003202166 and the part number for the sensing electrode is 3003202102

< Go Back2017-03-25

Heat Lline Capriz 28 - hot water is lukewarm - diverter valve service kit 3003202082

Heat Lline Capriz 28 combination boiler  

Fault description

  • Hot water is lukewarm

How to fix

  • Let the heating pipes to cool down
  • Open a hot water tap on full
  • Touch the boiler central heating flow pipe and notice if its getting hot
  • If its getting hot with hot water running then replace the diverter valve (recommended) or replace the insides
  • Replacement part is Black Nut Kit For Diverter Valve Heatline D003202082 3003202082

PDF - Heat Lline Capriz 28 - hot water is lukewarm - diverter valve service kit 3003202082 - installation instructions

< Go Back2014-12-24

Heat Lline Vizo 24 - Faulty Diverter valve 3003200017

Heat Lline Vizo 24 - the boiler fires up but no heating

  • Turn on heating and touch the hot water heat exchanger
  • If its getting hot when all the hot water taps are closed then a Diverter valve or a motor is faulty
  • Replacement part is Heatline Diverter Valve D003200017 (Replaces Part Number: 3003200017)
< Go Back2014-02-16