Switch to mobile site
Loading

Maintenance and Service

Triton

Click to open/close The Main Menu

Showers

Aqualisa

Armitage Shanks

Bristan

Crosswater

Crosswater

Grohe

HUB-001A-WAX Vado Thermostatic Cartridge

Hansgrohe

Hudson Reed

IB

Mira

Porcelanosa

S960134NU Thermostatic Cartridge

Sirrus Rothwell R995 Antique Shower

Swadling

Trevi

Triton

Triton

Ultra

Vado

Vola

Boilers

Alfa Laval

Alpha

Ariston

Baxi

Biasi

Chaffoteaux

Electroheat PLC

Ethos

Ferroli

Glowworm

Halstead

Heat Lline

Ideal

Keston

Main

Myson

Nibe

Potterton

Remeha

Saunier Duval

Vaillant

Viessmann

Vokera

Worcester

Taps

Armitage Shanks

Grohe

Hansgrohe

Ideal

Ideal Standard/Armitage Shanks

Mayfair

Phoenix

S960025NU Cartridge Replacement

Space Heaters

Baxi

Multiglow

Bathstore Thermostatic Cartridge

Servicing Guide

Pumps

Grundfos

Thermal Store Cylinders

Pulsacoil

Underfloor Heating

PolyPlumb

Toilets

Geberit

Grohe

Hot Water Cylinders

Dimplex

Megaflow

Santon

Gas Safety Inspection

Gas Flue Analysers

Gas Hobs

AGA

Neff

 

Triton Thermostatic cartridge 83307770 Replacement Tips

These very simple tips will aid you in replacing the Triton 83307770 thermostatic cartridge.

- Hot and cold water supplies must be isolated to prevent injuries. 

- Taping or plugging the drain will prevent small parts, like screws, from falling in. 

- The handle lever can be removed by hand; unscrew it anti-clockwise. 

- Remember the position of the temperature limiter's "stop" before removing it from the valve. This part must be re-installed in the same position. 

< Go Back2020-06-08

Triton Combi HP - thermostatic shower water is too cold

Triton Combi HP - thermostatic shower water is too cold

The thermostatic cartridge inside the shower valve is faulty. Need to replace the cartridge. Need to isolate the cold and hot water supply to the shower before replacing.

The part number is 83304970

< Go Back2019-07-22

Triton Dart 3 Thermostatic Cartridge Service Kit 8

Here are some solutions to problems with Triton shower valves using the 83312810 Triton thermostatic cartridge service kit:

 

Problem: Leaking concentric Triton valve.

Solution: Deteriorated seals might be the cause of the problem. Getting a new Triton 83312810 cartridge kit is necessary.

 

Problem: Shower water temperature fluctuates.

Solution: If the hot water supply to the shower is continuous, the thermostatic cartridge might have failed.

 

Problem: The threads of the cartridge are stuck together.

Solution: The threads have to be turned anti-clockwise. Spraying the cartridge with WD-40 can loosen the calcification.

< Go Back2019-07-18

Triton 83310120 Thermostatic Cartridge Problem - No Hot Water or No Cold Water

If only hot water or cold water is coming out of your shower, there are several reasons this could be.  To determine the problem, follow the following steps:

1.  Make sure there is hot water entering the shower.

2.  If there is, the problem could be a pressure issue whereby some shower valves struggle to mix when there is too much pressure from either the hot or the cold feeds.  If your shower was previously working then this shouldn't be a problem as it's likely your pressure will be the same as before.

3.  Now, turn off or isolate the water to the shower.

4.  Remove the 82210120 thermostatic cartridge.  This will remove by pulling it out (not a screw fit).

5.  Make sure there is nothing blocking the cartridge inlets.

6.  If nothing is blocking then it's probably an issue with the inner workings of the cartridge and the cartridge will need to be replaced.

7.  The part needed is the Triton 883310120 thermostatic cartridge.  

8.  This cartridge is also used on Triton Norina, Dart 2, Amala, Altessa, Cassini and Sentiment shower valves.

< Go Back2015-09-18

Triton Triton dart 2 concentric shower valve - thermostatic cartridge replacement 83310120

Triton dart 2 concentric shower valve turn on and off handle is very stiff to open or close

  • Thermostatic cartridge needs to be replaced
  • Waters supply must be isolated before replacing the part
  • The part number is 83310120
< Go Back2014-09-21

Triton Unichrome Tees temperature control is too stiff

Triton Unichrome Tees Square Bar - can't regulate the water temperature. The water temperature regulator is too stiff to turn.