Boiler Interlock
- Building Regs 2002 - Part L
- the boiler and pump are switched off if there is no heat demand
- Floor area is up to 150m2 - at least 2 space heating zones with independent temperature control (one is assigned to living area)
- Floor area is greater than 150m2 - at least 2 space heating zones with separate timing and temperature controls
- Single-storey open-plan (leaving area is greater than 70%) - sub-zoning is not appropriate
Heating Zones
- separate hot water zone in addition to space heating zone for all dwellings (not required for instantaneous heaters)
Timing Controls
- Full Programmer with separate timing to each circuit OR
- Two or more separate timers for each circuit OR
- Programmable room thermostats to the heating circuits with separate timing of the hot water circuit
- ONLY time control for space heating zones is required in case of instantaneous heater
Tempearture Controls
- Space Heating
- Room Thermostats or Programmable Room Thermostats in all zones
- Thermostatic Radiator Valves TRV's on all radiators (other than with thermostat and bathrooms)
- Domestic Hot Water
- Cylinder thermostat
- connected 1/3 up from the bottom of the cylinder
- set at 60-65°C
- controls a Motorised Valve
- if greater than 150m2 - more than one hot water circuit:
- multiple heating zone programmers
- a single multi-channel programmer
- separate timers for each circuit
- NO non-electric controls should be used