Boiler Sizing

  • Total up the sum of all the heat losses from the rooms and add an allowance for pipework heat losses and hot water
    • Pipe heat-loss allowance - 10% (if fair proportion of pipework is installed under suspended timber floor or in the loft)
    • Hot water heat requirement - 1kW of boiler heat for every 50 litres
< Go Back2013-04-18

Whole House Boiler Sizing Method

    • the method is usually preferred for determining the boiler output when replacing an existing oil or gas fired boiler
< Go Back2013-04-18