Central Heating pipework Sizing, layout and arrangement, Micro Bore, SEDBUK Rating, Boilers: Solid Fuel, Gas Fire with Back Boiler, Free-standing, Oil Fired, Natural Gas, Range Rated, Condensing, Combination, Regular, System. Flues types: Open Flue, Balanced Flue, Fan Assisted Flue, Boiler Sizing Formula, Whole House Boiler Sizing Method, Part L Building Regulations, Circulating Pump, Boiler Interlock, Pump Sizing, Central Heating System Controls, Programmer, Timer, Room Thermostat, Cylinder Thermostat, Automatic Bypass Valve, Air Release Valve, Motorized Valves, Pipe Frost Thermostat, Anti-gravity Valve, Air Separator, Thermostatic Radiator Valve TRV, Pressure Gauge, Heat Emitters, Convectors, Radiators, Heat Loss Calculation, Ventilation Rates, U-values, Choosing a Radiator, Radiation Correction Factor - f2, Temperature Difference Factor - f1
mob
07898 737 837
tel
0208 001 5260
Home
Services
Plumbing
Boiler Repairs
Pulsacoil Repairs
Shower Repairs
Extra
Plumbing Pages
Principles
Processes
Cold Water
Hot Water
Heating
Electrics
Lead
Sanitation
Unvented
Maintenance
Work Relations
Environment
Gas Safety
Gas Appliances
System Planning
News
Tax Calculator
About Us
Vaillant Products
Reviews
Portfolio
Vacancies
Terms and Conditions
Disclaimer
Contacts
Get a quote
Offers
New Boilers
Gas Check +
Powerflush
Loading
Central Heating
Exam revision materials for Plumbing Level 2&3 and ACS Gas Safety test
Create an Article
Boilers
Flue Types
Click to show/hide index
Maintenance
Commissioning
Water Treatment
Heating system water analysis
Dissolved copper test
Why to test?
pH test
Dissolved iron test
Servicing
BS 7593:2019
Repairs
Controls
Circulating Pump
Pump Location
Boiler Interlock
Pump Sizing
Heating System Controls
Load compensation
Drayton Wireless Digistat and RF Room Thermostat
Honeywell ST9400A & ST9400C Programmer Installation
Frost Thermostat
Pressure Gauges
Thermostatic Radiator Valves
Air Separator
Anti-gravity Valve
Pipe Frost Thermostat
Electromechanical Time Switch
Motorized Zone Valves
Air Release Valve
Automatic Bypass Valve
Cylinder Thermostat
Room Thermostat
Boiler Energy Manager
Programmer/Timer
Minimum Requirements
Part L Building Regulations
Room Thermostats
Honeywell Y6630D Room Thermostat Wireless
Wireless
Boilers
Boiler Sizing
Boiler Sizing
Whole House Boiler Sizing Method
Flue Types
Open Flued Boilers
Balanced Flue Boilers
Fan Assisted Flues
Gas Boilers
Modulating boilers
Range Rated Boilers
Condensing Boilers
Combination Boilers
Boiler Components
Regular Boilers
Heat Pumps
Air to Air Pump
Geothermal Energy
Oil Fired Boilers
Oil Fired Boilers
SEDBUK Rating
SEDBUK Rating
Solid Fuel Boilers
Solid Fuel Boilers
Solid-fuel Gas Fire with Back Boiler
Free-standing Boilers
Radiators
Where Should You Install a New Radiator?
Compact Radiator
Regulations
Regulations
Regulations
Heat Emitters
Heat Loss Calculation
Heat Loss through Ventilation
Room Temperature and Ventilation Rates
U-values of Building Fabric
Radiator Sizing
Formulas
Radiation Correction Factor - F2
Temperature Difference Factor - F1
Types
Convectors
Radiators
Fan Convector Heaters
Radiator Controls
Pipework
Fully Pumped Hot Water and Central Heating
Fully Pumped Domestic Hot Water and Central Heating System
Gravity Hot Water and Pumped Central Heating
Gravity Hot Water and Pumped Central Heating
Gravity System
Gravity System
Open-vented System
F&E Tank or Feed and Expansion Cistern
Open Vent Pipe
Air Separator
Pipework Sizing
Sizing
Pipework Systems
One Pipe System
Two Pipe System
Two Pipe Reverse Return
Micro Bore
Sealed Systems
Components
Expansion Vessel
System Layout
Bonding
Most Common Systems
Underfloor Heating
Underfloor Heating
Open Flued Boilers
the warmer the flue the stronger the draught
min
25mm
gap between a flue and any combustible material