Float-operated Valves
- BS 1212 (50" MAX size)
- Part 1 (Portsmouth) NOT suitable for WC cisterns
- Part 2(~£8)- diaphragm type, brass
- Part 3 (~£7) diaphragm type, plastic
- Part 4 (Torbeck) used in WC (Equilibrium)
- 4 ½’’ Ball Valve (~£3) with 15mm valve
- Backplate - fixed at the point of connection of FOV
- can fix a hammering noise
- Tank Connector (15mm ~ £1.63) - used to make connection to FOV
- High and Low-pressure type (different size of the orifice)
- Delayed Action Float-operated Valve - essential with hydropneumatic pumped system as it is reducing a number pump's stop/start
< Go Back | 2013-03-06 |
Stop Valve
- BS 1010
- Used for shutting off the flow of water in a pipe
- For higher pressure applications
- PREFERED position 150mm above the floor level
< Go Back | 2013-03-06 |
Gate Valve
- BS 5154
- Used for distributing pipes and as the main stop cock
- Flanged Gate Valve (2"~ £110)
< Go Back | 2013-03-06 |
Plug Valves
- Spherical Plug Valve (22mm~£3; BS 6675) - Used before single outlet
- Lever-operated pattern
- Screwdriver-operated pattern
- Plug Valve  for above and below ground use (25mm~£36; BS 2580)
< Go Back | 2013-03-06 |
Drain Valve
- BS 2879-2
- Screwdown Type is only allowed by Water Regulations
- 150mm from the floor on a rising main
- Replacement of "O"-ring Packing Gland
< Go Back | 2013-03-06 |
Check Valves
- Single Check Valve
- BS 6282
- prior to water softener; unvented heating systems; sprinkler system supply; downstream of meters, PRVs
- Disc and Flap types - for low pressure
- Spring-assisted Recoil Valve - for high pressure
- Double Check Valve
- hose tap; standpipes; Portsmouth; shower fitting
- Shower Check Valve – unconstrained shower hose
- Pressure Reducing Valve
- small end denotes higher pressure on the drawing
- more about PRV
- Reduced Pressure Zone Valve RPZ
- the lowest relief outlet SHOULD terminate with AA air gap, MIN 300mm above the ground level
- MUST only be installed by a competent person, completed the special course
- MUST be tested every year with a special test equipment
- Signed Certificate of Competence MUST be sent to the customer and a copy to the Water Undertaker
- SHOULD be provided with a drain pipe via a Tundish
- MUST be away from any electrics
- Fix Single Check Valve if flactuation occurs
- Pressure Flushing Valve - is not allowed to be installed in a domestic residential dwelling
< Go Back | 2013-03-06 |